Low-code, multi-vendor, on-prem
The whole floor, on one runtime.
HORUS connects and sequences robots, PLCs, drives, and sensors from ABB, Universal Robots, UFactory xArm, KUKA, and Siemens over their native fieldbus, with FANUC and Allen-Bradley on the roadmap. Scroll to watch a mixed-vendor cell come online.
- ABB SocketServer
- RTDE
- Siemens S7
roadmap OPC UA, EtherNet/IP, PROFINET, Modbus TCP
Why HORUS exists
A floor speaks six dialects. The integrator pays for all six.
A real cell mixes vendors: an ABB arm, a Siemens PLC, a UR cobot, a gripper on its own controller. Each ships its own driver, its own tag syntax, its own idea of what "done" means. The integration ends up as bespoke glue code: brittle, undocumented, and impossible to hand over.
HORUS makes one bet: the floor is easier to reason about when a signal has one name, not one name per device. It connects controllers over their native bus, resolves their tags into a single typed address space, and lets you sequence the cell in low-code blocks you can diff and roll back. Every motion is validated server-side before a command reaches an arm.
-
1
typed address space
-
native
fieldbus, not per-vendor glue
-
on-prem
runs on the plant station
Phase 01: Discover
Point it at the cell. It wires itself in.
HORUS enumerates the controllers already on the floor and connects over their native bus, with no driver compiled per vendor. Today the hub speaks ABB SocketServer, RTDE and Siemens S7 at once; more buses are on the roadmap.
- FANUC
- Allen-Bradley
- Omron
- Mitsubishi
Phase 02: Map
Two controllers. Two protocols. One signal name.
Siemens S7-1500 / PROFINET
DB12.DBX4.2 BOOL
clamp_a closed
ABB OmniCore / SocketServer
DI_clampClosed BOOL
clamp closed?
Resolves to one typed signal
cell.clamp_a.closed : bool
Reference the meaning. The runtime handles where it lives, how it's read, and which device drives it. Read by the sequence, the HMI, and the audit log alike.
Phase 03: Run
Watch it run. Keep every signal.
Every sensor and actuator signal is logged on the plant station with its timestamp. KPIs are computed from that history and projected forward, so drift shows up before it costs a shift.
Cycle time
4.81s
- 7-day avg
- Next shift
- 4.88s
- 4.78s
Throughput
702 parts/h
- 7-day avg
- Next shift
- 688
- 709
Availability
96.4%
- 7-day avg
- Next shift
- 95.1%
- 96.8%
Scan
1.9ms
- 7-day avg
- Next shift
- 2.0ms
- 1.9ms
- logged
- projected
- target
Projected: cycle time reaches the 4.75 s target in about 3 shifts if the trend holds.
- 41,288
ir.part_present
sensor / S7 I0.3 / on change
- 18,204
clamp_a.closed
sensor / ABB DI / on change
- 9,876
conveyor.run
actuator / S7 Q0.1 / on change
- 20,512
gripper.close
actuator / xArm TGPIO / on change
- 151,204,880
axis_2.speed
actuator / UR RTDE / 125 Hz
- 20,481
cell.cycle_time
KPI / derived / per cycle
Timestamped on the plant station
- 01
Discover
Enumerate every controller, drive, and I/O point over its native bus.
- 02
Map
Resolve vendor tags into one typed address space; name a signal once.
- 03
Sequence
Lay out interlocks and handshakes as explicit, diff-able blocks.
- 04
Run
Deploy on-prem, log every sensor and actuator, track and project KPIs, roll back cleanly.
Safety & deployment
The backend decides. Nothing moves until it says so.
The browser is a view. Every command routes through one server-side control layer that owns motion, safety, and the audit trail.
Validated before motion
Every pose checked against the cell
A robot's reach annulus intersected with the table polygon is the only allowed area. Each target pose and path is validated against it, and against Z limits and boundary distance, before any adapter command leaves the server.
Speed scales with distance
Slow near the edges, full in the clear
- < 10 mm → 0 %
- < 50 mm → 20 %
- < 100 mm → 50 %
- else → 100 %
Motion is blocked outright when the cell is disconnected, disabled, in E-stop, or the path leaves the allowed area.
Runs on the plant station
On-prem, loopback, no cloud round-trip
HORUS ships as a desktop app that supervises its backend on a local loopback port, so control never leaves the station. A Supabase project holds configuration, the device catalog, and the audit log; one build serves any plant via runtime config.
The software E-stop is not safety-rated. It is a software stop only. Hard interlocks (E-stop, light curtains, door switches) must be wired into the PLC and safety relay. HORUS sits on top of an already-safe cell; it does not replace functional safety.
Research & publications
Measured against the tools engineers already use.
HORUS grew out of controlled user studies at Tecnológico de Monterrey: real cobots, timed tasks, and the native teach pendant as the baseline.
-
2027 NAMRC 55, Manufacturing Letters (Elsevier)
Programming sensor-triggered palletizing in a pre-configured cobot cell: a low-code interface versus the teach pendant
Adrián Salazar, Lizeth Peña, Alfonso Villarreal, Erick Ramírez-Cedillo
- UR3e cell
- IR sensor + conveyor
- 22 participants
- HORUS vs. PolyScope
Key result
8.4 min
median time to first successful run with HORUS, against 39.4 min with the teach pendant
Holm-adjusted log-rank p = 0.011. Completion rate, interventions, SUS, NASA-TLX and IMI did not differ significantly.
-
2026 LoDISA, presented at the University of Cambridge, Sept 2026
Closing the gap between coding and deployment: evaluating a low-code GUI for cobot pick-and-place and palletising tasks
Adrián Salazar, Alfonso Villarreal, Lizeth Peña, Fernanda De la Cruz, Erick Ramírez-Cedillo, David Romero, Ciro A. Rodriguez
- xArm6 cobot
- vision-assisted positioning
- 30 participants
- 3 groups
Key result
73.1%
shorter mean completion time for experts using the GUI vs. without it
Non-experts using the GUI had a 47.1% shorter mean completion time than experts without it. Both GUI groups rated usability acceptable to good on the SUS.
The team
Built by the people who ran the experiments.
Three engineers from the MIT-Tec FrED Factory at Tecnológico de Monterrey, where the HORUS Automation team started. We build HORUS and run the user studies that test it.
-
Adrián Salazar
Visiting Researcher, MIT Device Realization Lab
Former Lead Project Manager of the Device team at MIT-Tec FrED Factory, now a Visiting Researcher at MIT's Device Realization Lab, working on process monitoring and closed-loop quality control for fiber extrusion.
-
Lizeth Peña
Visiting Researcher, MIT Device Realization Lab
Former Lead Project Manager of the Factory team at MIT-Tec FrED Factory, now a Visiting Researcher at MIT's Device Realization Lab, integrating operator motion sensing into the factory's MES so manual work is tracked step by step, like the machines.
-
Alfonso Villarreal
Instrumentation & Control Engineering Intern, CFE
Former Project Manager of the Horus Automation team at FrED Factory, now an Instrumentation and Control Engineering Intern at CFE.
Research advised by Dr. Erick Ramírez-Cedillo, Tecnológico de Monterrey
Straight answers
What actually ships, and what doesn't.
Which controllers can it actually drive today?
ABB (RAPID SocketServer over TCP), UFactory xArm, Universal Robots (ur-rtde: adapter complete, physical hardware validation pending), and KUKA, plus Siemens S7 PLCs over snap7. FANUC, Allen-Bradley, Omron and Mitsubishi are on the roadmap, not yet wired.
Which protocols are live versus roadmap?
Live today: ABB's SocketServer (TCP), RTDE for Universal Robots, and Siemens S7 / snap7. OPC UA, EtherNet/IP, PROFINET and Modbus TCP are planned. We'd rather list them as roadmap than claim them.
Cloud or on-prem?
On-prem. The runtime ships as a desktop app that supervises a local backend on a loopback port, so it runs on a plant station, not our servers. A Supabase project holds configuration, the device catalog, and the audit trail; one build serves any plant via runtime config.
Is the E-stop safety-rated?
No. HORUS's software E-stop is a software stop only. It is not a safety-rated function. Hard interlocks (E-stop, light curtains, door switches) must be wired into the PLC and safety relay. HORUS sits on top of an already-safe cell; it does not replace it.
How does access work?
We onboard integration partners one line at a time. Bring a single cell with its real controllers and we map it with you, so you see what it takes to resolve your tags into one address space before committing the floor.
Early access for integration partners
Bring one line. We'll map it with you.
Tell us the controllers on your floor, the protocols in play, and one line to start with. An engineer answers, not a sales sequence.
What to send
- controllers + firmware
- protocols / fieldbus
- one cell to pilot
Deployment
On-prem
Installed on a plant station. We can walk a pilot integration on your hardware, on-site or over a screen-share.
Region: TBD